This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 422.095(7)(d)1. 1. The emission control system has a minimum overall emission reduction efficiency of 85% for VOC emissions, as determined in accordance with s. NR 439.06 (3) (am).
NR 422.095(7)(d)2. 2. The emission control system has a minimum VOC capture efficiency of 90% and an output of VOC emissions of less than 50 ppm calculated as carbon, not including methane and ethane, with no dilution, as determined in accordance with s. NR 439.06 (3) (a).
NR 422.095(7)(e) (e) General prohibitions. The owner or operator of a facility may not atomize any solvent or solvent solution unless the resulting VOC emissions are controlled by an air pollution control system that meets one of the requirements of par. (d).
NR 422.095(7)(f) (f) Alternative compliance option. In lieu of complying with the requirements in par. (a), the owner or operator of a facility may use solvents or solvent solutions for industrial cleaning operations which have a VOC composite partial vapor pressure of less than or equal to 8 mm of Hg at 20°C.
NR 422.095(8) (8)Recordkeeping. In addition to the applicable recordkeeping requirements in s. NR 439.04, the owner or operator of any automobile refinishing operation shall collect and record the applicable information specified in this subsection. The information shall be maintained at the facility for a minimum of 5 years and shall be made available to a department representative at any time during normal working hours. The information required is:
NR 422.095(8)(a) (a) For each operation that is exempt under sub. (2) (f), the daily quantity in fluid ounces of VOC-containing aerosol product used for industrial cleaning operations.
NR 422.095(8)(b) (b) For each operation that is subject to sub. (7), the following information as appropriate:
NR 422.095(8)(b)1. 1. The name and identification of each cleaning material and the associated solvent cleaning activity.
NR 422.095(8)(b)2. 2. The VOC content of each cleaning material, in pounds per gallon of material, as employed or the VOC composite partial vapor pressure of the solvents or solvent solutions used in industrial cleaning operations.
NR 422.095(8)(b)3. 3. For any operation subject to sub. (7) (d), the results of any testing conducted as required under sub. (7) (d).
NR 422.095 History History: Cr. Register, August, 1995, No. 476, eff. 9-1-95; am. (1), (2) (a), (3) (a) (intro.), (b), (5) (intro.), (6) (intro.) and (7), r. (2) (c), (6) (a), (b) and (8), r. and recr. (4), renum. (6) (c) to (f) to be (6) (a) to (d) and am. (6) (d), Register, January, 2001, No. 541, eff. 2-1-01; CR 00-174: am. (4) (a) to (d), renum. Table 1 to be Table 2, Register August 2001 No. 548, eff. 9-1-01; correction in (6) (b) made under s. 13.92 (4) (b) 7., Stats., Register July 2009 No. 643; CR 11-005: renum. (1) to be (1) (a) and am., r. (6), cr. (1) (b), (2) (c) to (i), (7), (8), am. (2) (a) Register January 2012 No. 673, eff. 2-1-12, correction in numbering made to (6m) renum. from (7) made under s. 13.92 (4) (b) 7., Register January 2012 No. 673.
NR 422.10 NR 422.10Furniture metal coating — part 1.
NR 422.10(1)(1)Applicability. This section applies, subject to the provisions of s. NR 425.03, to the application areas, flashoff areas and ovens of furniture metal coating lines involved in prime and topcoat or single coating operations. This section does not apply to sources exempted under s. NR 422.03.
NR 422.10(2) (2)Emission limitations. No owner or operator of a furniture metal coating line may cause, allow or permit the emission of any VOCs in excess of 0.36 kilograms per liter of coating (3.0 pounds per gallon), excluding water, delivered to each coating applicator from prime and topcoat or single coat operations.
NR 422.10 History History: Renum. from NR 154.13 (4) (h) and am. Register, September, 1986, No. 369, eff. 10-1-86; am. (2), Register, February, 1990, No. 410, eff. 3-1-90; CR 08-102: am. (title) Register July 2009 No. 643, eff. 8-1-09.
NR 422.105 NR 422.105Furniture metal coating — part 2.
NR 422.105(1)(1)Applicability. This section applies to facilities which are located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Sheboygan, Washington, or Waukesha and have VOC emissions, before consideration of controls, equal to or exceeding 3 tons on a 12 consecutive month rolling basis from the application of coatings, including any related cleaning activities, to metal furniture. For purposes of this section, coatings include paints, sealants, caulks, inks, adhesives or maskants, but do not include metal protection oils, acids and bases.
NR 422.105(2) (2)Exemptions. The following coating types are exempt from the emission limitations in sub. (3):
NR 422.105(2)(a) (a) Stencil coatings.
NR 422.105(2)(b) (b) Safety-indicating coatings.
NR 422.105(2)(c) (c) Solid-film lubricants.
NR 422.105(2)(d) (d) Electric-insulating and thermal-conducting coatings.
NR 422.105(2)(e) (e) Touch-up and repair coatings.
NR 422.105(2)(f) (f) Hand-held aerosol can coatings.
NR 422.105(3) (3)Emission limitations. On and after May 1, 2010, no owner or operator may cause, allow or permit the emission of any VOCs in excess of limits listed in Table 2A. Notwithstanding s. NR 422.04 (4), an owner or operator using a control device to achieve compliance with this subsection as allowed under s. NR 422.04 (2) (c), shall achieve a minimum overall VOC control efficiency of 90%. - See PDF for table PDF
NR 422.105(4) (4)Application equipment and methods. No owner or operator of a furniture metal coating line subject to sub. (3) may apply coatings unless one of the following types of high transfer efficiency application equipment is used in accordance with the manufacturer's recommendations:
NR 422.105(4)(a) (a) Electrostatic application.
NR 422.105(4)(b) (b) Low-pressure spray method.
NR 422.105(4)(c) (c) Flow coating.
NR 422.105(4)(d) (d) Roll coating.
NR 422.105(4)(e) (e) Dip coating, including electrodeposition.
NR 422.105(4)(f) (f) A coating application method demonstrated to the department to be capable of achieving a transfer efficiency equivalent to or better than that achieved by low-pressure spray method, and for which written approval of the department has been obtained.
NR 422.105(5) (5)Work practices. On and after November 1, 2009, the owner or operator of a furniture metal surface coating facility shall employ work practices to minimize VOC emissions from mixing operations, storage tanks and other containers, and handling operations for coatings, thinners, cleaning materials, and waste materials. Work practices shall include all of the following, at a minimum:
NR 422.105(5)(a) (a) Store all VOC-containing coatings, thinners, coating related waste materials, cleaning materials, and shop towels used for cleaning in closed containers.
NR 422.105(5)(b) (b) Close mixing and storage vessels used for VOC-containing coatings and other materials except when depositing or removing these materials.
NR 422.105(5)(c) (c) Convey VOC-containing coatings, thinners, and cleaning materials in closed containers or pipes.
NR 422.105(5)(d) (d) Minimize spills of VOC-containing coating, thinners, and cleaning materials.
NR 422.105(5)(e) (e) Minimize emissions of VOC during cleaning of coating application, storage, mixing, and conveying equipment.
NR 422.105(5)(f) (f) Clean-up spills of any VOC-containing material immediately.
NR 422.105 History History: CR 08-102: cr. Register July 2009 No. 643, eff. 8-1-09; CR 11-005: am. (5) (b) Register January 2012 No. 673, eff. 2-1-12.
NR 422.11 NR 422.11Surface coating of large appliances — part 1.
NR 422.11(1)(1)Applicability. This section applies, subject to the provisions of s. NR 425.03, to application areas, flashoff areas and ovens of large appliance coating lines involved in single, prime or topcoat coating operations. This section does not apply to:
NR 422.11(1)(a) (a) Sources exempted under s. NR 422.03.
NR 422.11(1)(b) (b) The use of quick-drying lacquers for repair of scratches and nicks that occur during assembly, provided that the volume of coating does not exceed 0.95 liters (1 quart) in any one 8-hour period for any appliance coating line.
NR 422.11(2) (2)Emission limitations. No owner or operator of a large appliance coating line may cause, allow or permit the emission of any VOCs in excess of 0.34 kilograms per liter of coating (2.8 pounds per gallon), excluding water, delivered to each coating applicator from single, prime or topcoat coating operations.
NR 422.11 History History: Renum. from NR 154.13 (4) (i) and am. Register, September, 1986, No. 369, eff. 10-1-86; am. (2), Register, February, 1990, No. 410, eff. 3-1-90; CR 08-102: am. (title) Register July 2009 No. 643, eff. 8-1-09.
NR 422.115 NR 422.115Surface coating of large appliance — part 2.
NR 422.115(1)(1)Applicability. This section applies to facilities which are located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Sheboygan, Washington or Waukesha and have VOC emissions, before consideration of controls, equal to or exceeding 3 tons on a 12 consecutive month rolling basis from large appliance surface coating, including any related cleaning activities. For purposes of this section, coatings include paints, sealants, caulks, inks, adhesives, and maskants, but do not include metal protection oils, acids and bases.
NR 422.115(2) (2)Exemptions. The following coating types are exempt from the emission limitations in sub. (3):
NR 422.115(2)(a) (a) Stencil coatings.
NR 422.115(2)(b) (b) Safety-indicating coatings.
NR 422.115(2)(c) (c) Solid-film lubricants.
NR 422.115(2)(d) (d) Electric-insulating and thermal-conducting coatings.
NR 422.115(2)(e) (e) Touch-up and repair coatings.
NR 422.115(2)(f) (f) Hand-held aerosol can coatings.
NR 422.115(3) (3)Emission limitations. On and after May 1, 2010, no owner or operator may cause, allow or permit the emission of any VOCs in excess of limits listed in Table 2B. Notwithstanding s. NR 422.04 (4), an owner or operator using a control device to achieve compliance with this subsection as allowed under s. NR 422.04 (2) (c), shall achieve a minimum overall VOC control efficiency of 90%. - See PDF for table PDF
NR 422.115(4) (4)Application equipment and methods. No owner or operator of a large appliance surface coating line subject to sub. (3) may apply coatings unless one of the following types of high transfer efficiency application equipment is used in accordance with the manufacturer's recommendations:
NR 422.115(4)(a) (a) Electrostatic application equipment.
NR 422.115(4)(b) (b) Low-pressure spray method application equipment.
NR 422.115(4)(c) (c) Flow coating.
NR 422.115(4)(d) (d) Roll coating.
NR 422.115(4)(e) (e) Dip coating, including electrodeposition.
NR 422.115(4)(f) (f) Any other coating application method demonstrated to the department to be capable of achieving a transfer efficiency equivalent to or better than that achieved by low-pressure spray method, and for which written approval of the department has been obtained.
NR 422.115(5) (5)Work practices. On and after November 1, 2009, the owner or operator of a large appliance surface coating facility shall employ work practices to minimize VOC emissions from mixing operations, storage tanks and other containers, and handling operations for coatings, thinners, cleaning materials, and waste materials. Work practices shall include all of the following, at a minimum:
NR 422.115(5)(a) (a) Store all VOC-containing coatings, thinners, coating related waste materials, cleaning materials, and shop towels used for cleaning in closed containers.
NR 422.115(5)(b) (b) Close mixing and storage vessels used for VOC-containing coatings and other materials except when depositing or removing these materials.
NR 422.115(5)(c) (c) Convey VOC-containing coatings, thinners, and cleaning materials in closed containers or pipes.
NR 422.115(5)(d) (d) Minimize spills of VOC-containing coating, thinners, and cleaning materials.
NR 422.115(5)(e) (e) Minimize emissions of VOC during cleaning of coating application, storage, mixing, and conveying equipment.
NR 422.115(5)(f) (f) Clean-up spills of any VOC-containing material immediately.
NR 422.115 History History: CR 08-102: cr. Register July 2009 No. 643, eff. 8-1-09; CR 11-005: am. (5) (b) Register January 2012 No. 673, eff. 2-1-12.
NR 422.12 NR 422.12Magnet wire coating.
NR 422.12(1)(1)Applicability. This section applies, subject to the provisions of s. NR 425.03, to the ovens of magnet wire coating operations. This section does not apply to sources exempted under s. NR 422.03.
NR 422.12(2) (2)Emission limitation. No owner or operator of a magnet wire coating oven may cause, allow or permit the emission of any VOCs in excess of 0.20 kilograms per liter of coating (1.7 pounds per gallon), excluding water, delivered to each coating applicator from magnet wire coating operations.
NR 422.12 History History: Renum. from NR 154.13 (4) (j) and am. Register, September, 1986, No. 369, eff. 10-1-86; am. (2), Register, February, 1990, No. 410, eff. 3-1-90.
NR 422.125 NR 422.125Wood furniture coating.
NR 422.125(1)(1)Applicability.
NR 422.125(1)(a)(a) This section applies to the wood furniture finishing operations of any wood furniture manufacturing facility which is located in the county of Kenosha, Milwaukee, Ozaukee, Racine, Sheboygan, Washington, or Waukesha, and whose maximum theoretical emissions of VOCs from all wood furniture finishing operations at the facility, including any related cleaning activities, is greater than or equal to 25 tons per year.
NR 422.125(1)(b) (b) This section applies, except for sub. (4m), to any wood furniture manufacturing facility which is located in the county of Kewaunee or Manitowoc, and whose maximum theoretical emissions of VOCs from all wood furniture finishing operations at the facility is greater than or equal to 25 tons per year.
NR 422.125(2) (2)Emission limitations. After September 1, 1996, no owner or operator of a wood furniture finishing operation may cause, allow or permit the emission of any VOCs in excess of the following limitations:
NR 422.125(2)(a) (a) General limits. Except as provided in par. (b), either of the following:
NR 422.125(2)(a)1. 1. 0.8 kilograms per kilogram of solids (0.8 pounds per pound), as applied, for topcoats only.
NR 422.125 Note Note: There is no restriction on the VOC content of the sealers used by those electing to comply under subd. 1.
NR 422.125(2)(a)2. 2. 1.9 kilograms per kilogram of solids (1.9 pounds per pound), as applied, for sealers and 1.8 kilograms per kilogram of solids (1.8 pounds per pound), as applied, for topcoats.
NR 422.125(2)(b) (b) Acid-cured alkyd amino coatings. When the owner or operator is using acid-cured alkyd amino vinyl sealers or acid-cured alkyd amino conversion varnish topcoats, any of the following:
NR 422.125(2)(b)1. 1. Where the sealer is an acid-cured alkyd amino vinyl sealer and the topcoat is an acid-cured alkyd amino conversion varnish topcoat, 2.3 kilograms per kilogram of solids (2.3 pounds per pound), as applied, for sealers and 2.0 kilograms per kilogram of solids (2.0 pounds per pound of solids), as applied, for topcoats.
NR 422.125(2)(b)2. 2. Where the sealer is not an acid-cured alkyd amino vinyl sealer and the topcoat is an acid-cured alkyd amino conversion varnish topcoat, 1.9 kilograms per kilogram of solids (1.9 pounds per pound), as applied, for sealers and 2.0 kilograms per kilogram of solids (2.0 pounds per pound), as applied, for topcoats.
NR 422.125(2)(b)3. 3. Where the sealer is an acid-cured alkyd amino vinyl sealer and the topcoat is not an acid-cured alkyd amino conversion varnish topcoat, 2.3 kilograms per kilogram of solids (2.3 pounds per pound), as applied, for sealers and 1.8 kilograms per kilogram of solids (1.8 pounds per pound), as applied, for topcoats.
NR 422.125(2)(c) (c) Strippable spray booth coatings. 0.8 kilograms per kilogram of solids (0.8 pounds per pound) for strippable spray booth coatings, as applied.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.